Real-time data logger with integrated SD memory card measures/records up to 4 separate temperature measurements simultaneously as well as temperature differential. Accepts Type K, J , R, S, E, T thermocouples and RTD probes.
Brand:
REED
Model:
R2450SD
Order No:
R2450SD
Condition:
NEW
Description
REED Instruments R2450SD Data Logging Thermometer
The R2450SD features Data hold, Max/Min functions, and an easy-to-read backlit LCD display. Using a SD card (max 16GB), a user can manually record up to 99 readings or automatically by selecting a desired sampling rate from 1 to 3600 seconds. Quickly generate an Excel file with raw data, all without the use of software. Optional accessories include a tripod and AC adapter for continuous long-term monitoring on up to 4 separate channels.
Features
Displays up to 4 separate measurements simultaneously
Accepts Type K, J , R, S, E, T thermocouples and RTD probes
Temperature differential (T1-T2), Max/Min and Data hold functions
User selectable °C, °F
Real-time data logger with integrated SD memory card
User selectable sampling rate from 1 to 3600 seconds
Easy-to-read backlit LCD display
Tripod mount for long-term monitoring
Low battery indicator and auto shut off
Included
Data Logging Thermometer
Beaded Wire Probe
Soft Carrying Case
Batteries
Specifications
Measurement Range
Type K
-148 to 2372°F (-100 to 1300°C)
Type J
-148 to 2102°F (-100 to 1150°C)
Type T
-148 to 752°F (-100 to 400°C)
Type E
-148 to 1652°F (-100 to 900°C)
Type R
32 to 3092°F (0 to 1700°C)
Type S
32 to 2732°F (0 to 1500°C)
RTD Pt100 Ohm
-327.9 to 1562°F (-199.9 to 850°C)
Accuracy
Type K
-148.0 to -58.1°F, ±(0.4% + 1.8°F)
-58.0 to 999.9°F, ±(0.4% + 1°F)
1000 to 2372°F, ±(0.4% + 2°F)
-100.0 to -50.1°C, ±(0.4% + 1°C)
-50.0 to 999.9°C, ±(0.4% + 0.5°C)
1000 to 1300°C, ±(0.4% + 1°C)
Type J
-148.0 to -58.1°F, ±(0.4% + 1.8°F)
-58.0 to 999.9°F, ±(0.4% + 1°F)
1000 to 2102°F, ±(0.4% + 2°F)
-100.0 to -50.1°C, ±(0.4% + 1°C)
-50.0 to 999.9°C, ±(0.4% + 0.5°C)
1000 to 1150°C, ±(0.4% + 1°C)
Type T
-148.0 to -58.1°F, ±(0.4% + 1.8°F)
-58.0 to 752.0°F, ±(0.4% + 1°F)
-100.0 to -50.1°C, ±(0.4% + 1°C)
-50.0 to 400.0°C, ±(0.4% + 0.5°C)
Type E
-148.0 to -58.1°F, ±(0.4% + 1.8°F)
-58.0 to 999.9°F, ±(0.4% + 1°F)
1000 to 1652°F, ±(0.4% + 2°F)
-100.0 to -50.1°C, ±(0.4% + 1°C)
-50.0 to 900.0°C, ±(0.4% + 0.5°C)
Type R
32 to 3092°F, ±(0.5% + 5°F)
0 to 1700°C, ±(0.5% + 3°C)
Type S
32 to 2732°F, ±(0.5% + 5°F)
0 to 1500°C, ±(0.5% + 3°C)
RTD Pt100 Ohm
-327.0 to 999.9°F, ±(0.4% + 1.8°F)
1000 to 1562°F, ±(0.4% + 2°F)
-199.9 to 850.0°C, ±(0.4% + 1°C)
Resolution
Type K
0.1°F (0.1°C)
1°F (1°C) ≥ 1000°
Type J
0.1°F (0.1°C)
1°F (1°C) ≥ 1000°
Type T
0.1°F (0.1°C)
Type E
0.1°F (0.1°C)
1°F ≥ 1000°
Type R
1°F (1°C)
Type S
1°F (1°C)
RTD Pt100 Ohm
0.1°F (0.1°C)
1°F ≥ 1000°
General Specifications
Resolution
0.1 or 1°F/°C
Type
4-Channel Thermocouple, 2-Channel RTD
Response Time
1x/second
Display
Quad Display, LCD
Backlit Display
Yes
Data Hold
Yes
Min
Yes
Max
Yes
Differential Measurement (T1-T2)
Yes
Datalogging Capabilities
Yes
Real-Time Clock and Date Stamp
Yes
Selectable Sampling Rate
Yes (1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds)
External Memory
Yes, expandable up to 16GB with SD card (optional)
Auto Shut-off
Yes (after 10 minutes/off)
Kick Stand
Yes
Tripod Mountable
Yes
Low Battery Indicator
Yes
Power Supply
6 x AA Batteries or AC Adapter (optional)
Data Output
Yes (RS-232)
Product Certifications
CE
Operating Temperature
32 to 122°F (0 to 50°C)
Storage Temperature
14 to 140°F (-10 to 60°C)
Operating Humidity Range
Less than 85% RH
Dimensions
7.0 x 2.7 x 1.8" (177 x 68 x 45mm)
Weight
0.6lbs (268g)
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.